AV3985 Electronic Measuring Device Millimeter Wave Noise Figure Analyzer

Brand Name : Graigar
Model Number : AV3985
Certification : CE/ROHS/SGS/ISO9001
Place of Origin : China
MOQ : 1 piece
Price : negotiation
Payment Terms : L/C, T/T, Western Union, MoneyGram, Paypal
Supply Ability : 1000 pieces per week
Delivery Time : 2 working days after received your payment
Packaging Details : Packed in carrying case firstly, and then reinforced with export carton for outer packing
Frequency Range : 10MHz~40GHz
Measurement Bandwidth : 4MHz, 2MHz, 1MHz, 400kHz, 200kHz, 100kHz
Noise Figure Measurement Range : 0~30dB (Noise Source ENR:14dB~16dB)
Gain Measurement Range : -20dB ~ +40dB
Gain Measurement Uncertainty : ±<0.17dB
Noise Source Switching Voltage : +28V±0.1V (On) <1V (Off)
Contact Now

AV3985 Electronic Measuring Device Millimeter Wave Noise Figure Analyzer

Product Overview:

AV3985 Millimeter-wave Noise Figure Analyzer adopts several high and new technologies such as wideband track pre-selection, wideband low-noise millimeter-wave amplification, multi-functional integrated miniature design, high-speed sweep measurement, embedded PC hardware platform, Windows 2000 software platform, and Chinese interface, which is easy of realizing high-precision measurement of noise figure and gain in linear or quasi-linear network of microwave and millimeter-wave at 10 MHz ~ 40 GHz. It is widely used in the measurement of noise figure and gain of microwave and millimeter-wave amplifier, mixer, attenuator, etc. components and devices and front end linear circuit part of receiver. In comparison with the foreign testing program for noise figure at wave band of 8mm achieved through spread spectrum, AV 3985 has been improved substantially in respect of frequency precision, noise figure precision and gain testing range, etc., representing the highest level of technology for testing noise figure at wave band of 8mm both at home and abroad.



Main Features:

ο Compact system configuration, integrated measurement of noise figure for RF, microwave and wave band of 8mm
ο Flexible and visual user interface
ο True color LCD, in dual-channel display of curve of noise figure and gain, etc. many parameters varying with frequency
ο Optional bandwidth at six resolutions
ο Perfect measurement function, allowing achievement of noise figure and gain measurement of amplifier, up and down converter, etc. components or system
ο With Loss compensation function, compensating the loss before and after DUT in the form of fixing, table and combination, for addressing the testing difficulty of millimeter-wave tube requiring deembedding
ο Abundant peripheral interfaces with high reusability
ο Available in dual noise source drive capability, supporting both common noise source and intelligent noise source, plug-and-play for the latter with ENR (excess noise ratio) automatic loading

οWide frequency coverage, compact system configuration

With wide frequency coverage, this instrument can measure the noise figure and gain within the frequency range from 10MHz to 40 GHz, compact design and good repeatability of system could minimize the error and uncertainty resulted from system setup. The integrated model replaces the complex testing system divided into microwave and millimeter-wave.

ο Flexible and visual user interface

Flexible and visual user interface is easy for use. All keys are arranged by function, as clear as day and easy of search. Simple layer of special function keys, only have several layers, clear layering of parent menu and submenus, and real-time display of instrument testing status on screen offers higher accuracy of measurement, prompt measurement tips and guide dialog box facilitate a faster and more accurate measurement.

ο True color LCD HD display

AV3985 Millimeter-wave Noise Figure Analyzer is provided with a 17cm true color LCD display on which the noise figure and gain variation with frequency are displayed, which improves the user’s comfort and distinctness. Moreover, it is also available in multiple display effects: three display formats, two independent channels, multiple combined curve graphics and up to six measurement results, etc.

οVariable measurement bandwidth

4MHz bandwidth is still applicable in noise testing system for many modern applications. However, the rapid development of wireless communication and increasing congestion of RF spectrum
gradually present demand for narrowband noise figure measurement. AV3985 Millimeter-wave Noise Figure Analyzer has variable measurement bandwidths and can realize actual measurement at bandwidth of different resolutions, i.e. 4MHz, 2MHz, 1MHz, 400kHz, 200kHz and 100kHz, which is critical for improving narrowband measurement precision.

ο Perfect loss compensation

Loss compensation function can compensate the loss in channels before and after DUT in the form of fixing, table and combination, which greatly facilitates testing on the microwave and millimeter-wave tube core requiring deembedding.

ο Abundant peripheral interfaces

Multiple peripheral interfaces, such as GP-IB, RS232, LAN, USB, VGA and universal computer keyboard and intelligent mouse interface, greatly facilitate re-setup of various applications and systems.

ο Dual noise source drive capability

Intelligent multi-core noise source drive interface is compatible with Agilent N4002 series intelligent noise source. The main unit can automatically identify connection of intelligent noise source and download ENR data; meanwhile it also can detect the change of operating temperature at real time for temperature correction of noise figure, thus improving the speed and accuracy of measurement.

Common noise source +28V pulse drive interface is compatible with the common noise sources from many manufacturers.


Typical Applications:

AV3985 Millimeter-wave Noise Figure Analyzer can measure the noise figure and gain of microwave and millimeter-wave amplifier, mixer and attenuator, etc. components and devices and various receivers. The measurement mode is divided into the following three types: amplifier mode, converter mode and system down conversion mode.

Technical Specifications

Frequency Range10MHz~40GHz
Measurement Bandwidth4MHz, 2MHz, 1MHz, 400kHz, 200kHz, 100kHz
Frequency Tuning Accuracy4MHz: ± (Frequency Reference Error+100kHz) 10MHz~3GHz
± (Frequency Reference Error+400kHz) 3GHz~40GHz
<4MHz: ± (Frequency Reference Error+20kHz) 10MHz~3GHz
± (Frequency Reference Error +Measurement Bandwidth×20%) 3GHz~40GHz
(Frequency Reference Error = Measurement Frequency Point × Reference
Frequency accuracy)
Noise Figure Measurement Range0~30dB (Noise Source ENR:14dB~16dB)
Noise Figure Measurement Uncertainty±<0.15dB (Noise Source ENR:14dB~16dB)
Gain Measurement Range-20dB ~ +40dB
Gain Measurement Uncertainty±<0.17dB
This Unit Noise Figure<7.5dB 10MHz~500MHz
<9.5dB 500MHz~3GHz
<12dB 3GHz~18GHz
<14dB 18GHz~26.5GHz
<14dB 26.5GHz~40GHz
Frequency Tuning Accuracy4MHz: ± (Frequency Reference Error +100kHz) 10MHz~3GHz
± (Frequency Reference Error +400kHz) 3GHz~40GHz
<4MHz: ± (Frequency Reference Error+20kHz) 10MHz~3GHz
± (Frequency Reference Error +Measurement Bandwidth×20%) 3GHz~40GHz
(Frequency Reference Error = Measurement Frequency Point × Reference
Frequency Accuracy)
Jitter
(Uneven)
<0.17dB (Y Factor Deviation)
Input connector type2.4mm (male)
Input Port Standing Wave Ratio<1.65:1 10MHz~500MHz
<1.90:1 500MHz~3GHz
<2.40:1 3GHz~18GHz
<2.50:1 18GHz~40GHz
Measurement Points2~401(or Fixed Frequency Measurement)
Noise Source Switching Voltage+28V±0.1V (On)
<1V (Off)
Power SupplyVoltage RangeAC220V±10%
Frequency Range50Hz±5%
Dimensions (W×H×D)360mm×177mm×502mm (Handle, foot pad, toe pad excluded)
420mm×211mm×580mm (Handle, foot pad, toe pad included)
WeightApprox.23kg

Order Information

  1. Main Unit

AV3985 Millimeter-wave Noise Figure Analyzer

  1. Standard Configuration
ItemDescriptionQty
Accessories of standard configurationPower Cord1
User’s Guide1
Quality Inspection Certificate1
  1. Options
No.DescriptionModelRemarks
1Intelligent millimeter-wave noise sourceAV16605Standard drive for noise figure testing
2.4mm-2.4mm
Dual female adaptor
(Noise Source Accessory)
2.4-2.4mmKKFor connecting noise source output with noise figure analyzer input
Multi-core cable
(Noise Source Accessory)
For connecting noise figure analyzer with noise source
2Common millimeter-wave noise sourceAV16605BStandard drive for noise figure testing
2.4mm-2.4mm Dual female adaptor
(Noise Source Accessory)
2.4-2.4mmKKFor connecting noise source output with noise figure analyzer input
BNC Cable
(Noise Source Accessory)
For connecting noise figure analyzer with noise source
3USB-GPIB Adaptor cardAgilent82357BFor control of system LO source by noise figure analyzer
(When the mixer or system down-converter under test run in fixed IF or SWP mode, and LO has corresponding control port, this adaptor card is used to achieve the auto-control of LO, and thus the auto-measurement)

Teny


Product Tags:

electronic measuring instruments

      

electronic measuring equipment

      
China Customized Inflatable Bumper Ball Game Bubble Adult Grass CE supplier

AV3985 Electronic Measuring Device Millimeter Wave Noise Figure Analyzer Images

Inquiry Cart 0
Send your message to this supplier
 
From:
Enter your email please.
To: Shenzhen Graigar Technology Co., Ltd
Subject:
Message:
Characters Remaining: (0/3000)