Custom Ultrasonic Wall-mount Flow Meter High Accuracy DN15 - DN100mm DN300 - DN6000mm

Shenzhen Graigar Technology Co., Ltd
Shenzhen Graigar Technology Co., Ltd
City: Shenzhen
Province/State: Guangdong
Country/Region: China
Tel: 86-755-27541660
Contact Person:Mr Lee

Custom Ultrasonic Wall-mount Flow Meter High Accuracy DN15 - DN100mm DN300 - DN6000mm

Brand Name : OEM
Model Number : TDS-100F
Certification : CE
Place of Origin : China
MOQ : 1 pieces
Price : negotiation
Payment Terms : T/T, Western Union, Paypal, L/C, MoneyGram
Supply Ability : 300 pieces per week
Delivery Time : 3 working days after received your payment
Packaging Details : Export carton
Suitable pipe diameter : DN15-6000mm
Fluid temperature : 0°c-160°c
Linearity : Better than ±1%.
Accuracy : ±1% of reading at rates >0.6 ft/s (0.2m/s). Assume a fully developed flow profile.
Repeatability : ±0.2%.
Velocity : ±0.03 ~ ±105 ft/s (±0.01 ~ ±30 m/s), bi-directional
Measurement Period : 0.5s
Display : LCD with backlight. 2x20 letters.
Contact Now

Fixed ultrasonic flowmeter TDS-100F wall-mount flow meter (DN15-6000mm)


Description:

Is stationary time difference ultrasonic flowmeter flow body could be water, sea water, or oil, uniform liquid slurry, conduct electricity or not, corrosive or no corrosive liquid can be measured. Widely used in industrial field of various liquid flow metering online, which host is divided into standard wall hanging type, plate type, hanging type explosion-proof, the use of different field in order to meet user needs.


Product features

Low fixed ultrasonic flowmeter with large planning integrated circuits CPLD, table process, accuracy is higher.

Price, high reliability, high performance, good applicability, full display in Chinese.

Day, month and year flow accumulation function, can record run 64 days before the operation, the first 64 months, the first five years of accumulated flow operation.

On low, the power management function, can record, electricity and traffic on 64 times before, can be manually or automatically compensate to reduce flow losses.

Low effectively overcome the wall of the ultrasonic signal attenuation and rough surface of the pipe to scattering of ultrasonic signal from surface reduce the energy consumption of ultrasonic signal.

Low overcame a signal to a small amount of sediment, suspended particles and bubbles, the effect of improved flow measurement accuracy, especially suitable for pipe flow measurement.

When using a dedicated open hole tool that sensor in the zone without water supply installation, unique belt roller disassembly, installation method, does not affect the normal production, at any time to complete the on-line replacement and maintenance.


Linearity

Better than ±1%.

Accuracy

±1% of reading at rates >0.6 ft/s (0.2m/s). Assume a fully developed flow profile.

Repeatability

±0.2%.

Velocity

±0.03 ~ ±105 ft/s
(±0.01 ~ ±30 m/s), bi-directional

Measurement Period

0.5s

Display

LCD with backlight. 2x20 letters.

Keypad

4x4-key membrane keypad with
tactile feedback

Units

English (U.S.) or metric.

Outputs

Analogue output: 4-20mA or 0-20mA current output. Impedance 0~1kW. Accuracy 0.1%. .

Isolated OCT output: for frequency output (0~9,999Hz), alarm driver, or totaliser pulse output, ON/OFF control, etc.
Relay output 1A@125VAC or 2A@30VDC. For ON/OFF control, alarm driver, totaliser output, etc.

Internal Alarm (Buzzer): user programmable.
External Alarm Driver: alarm signal can be transmitted to Relay or OCT output terminals to drive an external alarm.

RS-232 serial port.

Input

Five channel 4-20mA current inputs for signals such as temperature, pressure, liquid level, and etc.. Accuracy 0.1%.
Two of the five input channels are wired to terminal blocks. The remaining three channels are optional.

Enclosure

Die-cast aluminum enclosure.

Protection Class: IP65 (NEMA 4X).

Size: 9.88x7.56x3.15 (251x192x80mm3) for standard version

Clamp-on

S2-type: for pipe size (DN15~DN100mm)

M2-type: for pipe size (DN50~DN700mm)

L2-type: for pipe size (DN300~DN6,000mm)

Liquid Types

Virtually all commonly used clean liquids.

Liquids with small quantity of tiny particles may also be applicable. Particle size should be less than 75um, particle concentration less than 10,000ppm.

Liquids should contain no or very minor air bubbles.

Examples are chilled/hot water, sea water, waste water, chemical liquids, oil, crude oil, alcohol, beer, etc.

Liquid Temp

(0C - 160C) for clamp-on transducer. Higher temperatures can be accommodated. Consult the manufacturer for assistance.

(0C - 160C) for wetted transducer.

Pipe Size

1 ~ 240 (DN25mm ~ DN6,000mm).

Pipe Material

All metals, most plastics, fiber glass, etc. Allow pipe liner.

Cable

Shielded transducer cable. Standard length 15 (5m). Can be extended to 1640 (500m). Contact the manufacturer for longer cable requirement.

Power

AC: 240V DC: 8VDC~36VDC

Power consumption: < 2W

Weight

Standard main unit: 6.6lb (3kg)

Transducer

Standard S2 type

Standard M2 type

Standard L2 type



Suitable pipe diameter

DN15-DN100

DN50-DN700

DN300-DN6000



Fluid temperature

0°c-160°c

0°c-160°c

0°c-160°c



Outer size

45×30×30mm

60×45×45

80×70×55



Quality

75g

250g

528g



Standard Accessories:
TDS-100F ultrasonic flow meter 1 set
Clamp Fixture 1 set
Standard M2 transducer 1 pair (transducer S2 and L2 is optional)
2 x 2.5M Connection Cable


Product Tags:

high precision flow meter

      

ultrasonic flow meter

      
China Customized Inflatable Bumper Ball Game Bubble Adult Grass CE supplier

Custom Ultrasonic Wall-mount Flow Meter High Accuracy DN15 - DN100mm DN300 - DN6000mm Images

Inquiry Cart 0
Send your message to this supplier
 
From:
Enter your email please.
To: Shenzhen Graigar Technology Co., Ltd
Subject:
Message:
Characters Remaining: (0/3000)